Installation and alignment
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 66
7.4 Installation on the floor
Prerequisites
} The protective bracket PSENscbracketH must already be fixed at the safety laser scan-
ner (see Installation of the protective bracket PSEN sc bracket H at the safety laser
scanner [ 65]).
Procedure:
[5]
[7]
[6]
[8]
[1]
[2]
[3]
[4]
[4]
[3]
[7]
180
73
279,5
39,5
[2]
[1] Drill holes for attachment to floor PSEN sc installed on PSEN sc bracket F
[2] Through holes for fixing at PSENscbracketF
1. Fix PSENscbracketF with the fixing screws to the floor and tighten the fixing screws
alternately and evenly with 3 Nm.
2. Fix PSENscbracketPR or PSENscbracketP with the fixing screws to
PSENscbracketF and tighten the fixing screws alternately and evenly with 3 Nm.
3. Fix the adjusting disc for angle of inclination [1] with the set screw and washers [2] at
PSENscbracketP or PSENscbracketPR (right or left).
4. Align the middle of the adjusting disc for angle of inclination [1] with the center of the fix-
ing for the safety laser scanner [3] and tighten the set screw for the adjusting disc for
angle of inclination [2] with 2,5 Nm.
5. Insert the safety laser scanner in PSENscbracketPR or PSENscbracketP with the
bracket PSENscbracketH to the top and fix the safety laser scanner with the screws
[3] and [4]. Tighten all four screws to 3 Nm.
6. Set the angle of inclination of the safety laser scanner, if necessary. [ 69]
7. Set the side inclination of the safety laser scanner, if necessary [ 70].
7.5 Installation with setting of angle of inclination/roll angle -
bracket PSEN sc bracket PR
} The setting of the angle of inclination of the safety laser scanner is not changed when ex-
changing the safety laser scanner.
Prerequisites
} Mounting surface with 2 drill holes, 10mmdeep, distance 73mm horizontally towards
each other for fixing the PSENscbracketPR or PSENscbracketP