7 Installation and alignment
7.1 Installation options
The safety laser scanner can be installed in various ways.
} Installation directly at the mounting surface [ 64]
} Installation to the floor with PSEN bracket F [ 66]
} Installation with protective bracket PSEN sc bracket H [ 65]
} Installation with PSEN sc bracket PR for inclination to the side or to the top or
bottom [ 66]
} Installation with PSEN sc bracket P for inclination to the top and bottom [ 69]
7.2 Installation without PSEN sc bracket H
For direct installation of the safety laser scanner at the mounting surface, two threaded
holes are provided at the rear of the safety laser scanner.
Please note:
} With direct installation of the safety laser scanner at the mounting surface, the accessory
PSENscbracketH cannot be used.
} With direct installation of the safety laser scanner at the mounting surface, the safety
laser scanner cannot be inclined to the side or to the top/bottom.
} Ensure that the front panel of the safety laser scanners is not covered by a wall or an-
other plane. Note the distance to the walls [ 42].
} To fix the safety laser scanner, use M5 screws for a max. screw depth of 10 mm.
Legend
[1] Mounting surface
[2] M5 screws