Wiring
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 58
} When using the 17-pin connection, the configurable inputs at PINs 5, 6, 7, 9, 14 and 17
can be used for the following functions:
– Restart
– Reset
– Restart or reset
– EDM
– Zone set switching
– Muting 1 and 2
– Dynamic activation of the muting state
– Override
} When using the 17-pin connection and the 8-pin connection, the configurable inputs at
PINs 5, 6, 7, 9, 14 and 17 and PIN 8-1 to PIN 8-8 can be used for the following functions:
– Restart
– Reset
– Restart or reset
– EDM
– Zone set switching
– Muting 1 and 2
– Dynamic activation of the muting state
– Override
The configurable inputs for encoder can be used for input signals of encoders. When no en-
coders are used, these inputs can also be used as configurable inputs.
6.6 Wiring of the configurations
The configuration of the safety laser scanner PSEN sc ME 5.5 08-17 is carried out in
PSENscan Configurator on a configuration PC.
The wiring has to match the specifications in PSENscanConfigurator.
6.7 Connect supply voltage and safety controller
The supply voltage connection is in the memory module that is protected by a screwed-on
cover. The memory module can be uninstalled for simpler connection.
1. Turn the safety laser scanner PSEN sc ME 5.5 08-17 for better access to the memory
module.
2. Loosen the M3 screws of the protective cover and remove the protective cover.
The screws are secured against loss and they cannot be removed.