Operation
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 100
Message in the display Error/cause Description/measure
Icon Text
INTF18 An error occurred during the system
test.
Perform a reset of the safety laser
scanner [ 104].
If the error persists, please contact
Pilz.
INTF20 An error occurred during the system
test.
Perform a reset of the safety laser
scanner [ 104].
If the error persists, please contact
Pilz.
OSSD1F3 Earth fault has occurred on OSSD1. Check the EDM state and the wiring
of the OSSDs [ 54].
If the error persists, please contact
Pilz.
OSSDF1 An error has occurred when testing
the OSSD1.
Check the EDM state and the wiring
of the OSSDs [ 54].
If the error persists, please contact
Pilz.
10.3.2 Warnings
Message in the display Error/cause Description/measure
Icon Text
BOOTF An error has occurred when starting
the system.
Perform a reset of the safety laser
scanner [ 104].
If the error persists, please contact
Pilz.
INTF6 An error occurred during the system
test.
Perform a reset of the safety laser
scanner [ 104].
If the error persists, please contact
Pilz.
EXTTEMP The ambient temperature is outside
the temperature range indicated in
the Technical details.
Ensure that the ambient temperature
is in the temperature range specified
in the Technical details [ 115].
OVERTEMP The temperature of the safety laser
scanner is outside the permitted
temperature range.
HIGH REFL-
BKG
The reflection of the background is
too strong.
Reduce the background reflection or
increase the safety distance (see
Distance to intense light sources and
to reflective surfaces [ 40]).