First commissioning
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 94
Save the report in PDF format.
Click Reject to reject the downloaded configuration in the connected device and con-
tinue to use the existing configuration on the connected device. The downloaded con-
figuration in the connected device will be deleted.
9.4 Testing
Before finally commissioning the safety laser scanner after the installation and alignment, fi-
nal inspections must be carried out.
INFORMATION
This inspection may only be carried out by qualified personnel.
Check safety function of the safety laser scanner
Procedure:
As a test piece, use an opaque object with a height of at least 300 mm and a diameter that
corresponds to the selected detection capability.
Move the test piece at various points along the safety zone into the safety zone:
The OSSDs must switch to the OFF state with each entry of the test piece.
Supplementary test step for vertical applications
Change the position of the reference points beyond the tolerance range of the reference
points:
The OSSDs must switch to the OFF state with each change of the reference point beyond
the tolerance range.
Check ambient conditions and installation
} Correct alignment and fixing
Check that the fixing screws of the safety laser scanner are firmly seated.
} Safety distance
The safety distance must comply with the requirements in Maintaining the safety
distance [ 29].
} Circumventing the safety zone
The danger zone must be safeguarded so that it is impossible to access by circumventing
the safety zone.
} Safety zone perimeters
The safety zone perimeters (see Project configuration [ 28]) must completely safe-
guard the danger zone, making it inaccessible.
} Position of the pushbutton for manual restart
It must not be possible to operate the pushbutton for manual restart from inside the
danger zone. The pushbutton must be located at a position from which there is a full, un-
obstructed view of the danger zone.

Table of Contents