First commissioning
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 81
11. Select the detection capability [mm] for this safety laser scanner. Define the value for
each configured Safety zone and for each Warning zone.
12. Select Dust filter level (level1=low, level 3=high).
A higher level of dust filtering requires a longer safety distance.
WARNING!
Loss of safety function due to a safety distance that is too low
Depending on the application, serious injury or death may result.
} Depending on the degree of dust filtering, it is necessary to consider an
allowance for calculating the safety distance when installing the safety
laser scanner near intense light sources or reflective surfaces into ac-
count (see Distance to intense light sources and to reflective
surfaces [ 40]).
When calculating the safety distance, ensure that the allowance is
considered depending on the dust filtering.
Ensure that the new safety distance fulfils the specifications of the
safety assessment.
13. Click on the arrow . The next window Configure zones is opened.
Create the zones using the symbols in the tool bar on the right-hand side.
14. In the selection of zones, select Safety, select a shape and create the required shape.
The shape is displayed as the first zone in the selected safety zone.
15. Select the muting zone for the safety zone that was just created.
A warning is shown. With each change of safety zone, all the assigned muting zones
are deleted. Click OK.
16. Select whether the muting zone is to cover the whole safety zone.
The muting zone can still be changed at a later stage, however, not beyond the limits of
the safety zone.
Click Yes: The created muting zone covers the whole safety zone.
Click No: No muting zone is created. Select a shape and manually create a muting
zone.
17. Click on .
Specify at least 3 (max. 15) reference points. Specify a max. permitted tolerance for
each reference point. Tol - is the tolerance for the side that faces the safety laser scan-
ner, Tol + is the tolerance for the side that is facing away from the safety laser scanner.
18. Switch the display in the work window to a live image by clicking on .