Message in the display Status Description/measure
Icon Text
The status of the network is checked The status of the safety laser
scanner in the network is
checked.
ITLOCK1 Safety laser scanner in interlock con-
dition
The safety laser scanner is in
interlock condition. Normal op-
eration is possible only after a
successful restart of the safety
laser scanner.
INPUTCF1 Faulty input Faulty input, e.g. wrong number
of inputs that are used for
switching the zone sets.
NOCONF No configuration available No configuration for the safety
laser scanner could be found.
The wave function is activated. The symbol flashes. Select the
safety laser scanner in
PSENscan Configurator and
configure it.
MUT TIMEOUT Muting has elapsed (timeout).
MUTING ERR Could not activate muting because the
specifications for activating the muting
sensors were not met.
MUTING Muting on OSSD1 is active.
The OSSDs are in the ON state.
OVERRIDE ERR Could not activate override because
the specifications for activation were
not met.
OVERRIDE Override is active.
OVR TIMEOUT Override has elapsed.