5. When the Ambient Exposure Test reading is within specification, replace the Test Top
Cover with the camera’s own Top Cover.
Note: If adjusting the Ambient Calibration Slide fails to bring the readings within
specification, refer to Steps 4, 5 and 6 of the Ambient Exposure Test
procedure.
Figure 3-17. Adjusting ambient (visible light) calibration slide
Ambient
Calibration Slide