66
Sensitive S1
Typical causes:
• S1/S10 switch distorted
No Motor Drive
Typical causes:
• Motor connector not plugged into One Board
• VBATT wire (white) not connected to RM
• No contact from VER to battery (red wire) on strobe board
• Broken red wire
• Door switch not in correct position
• Motor pinion gear binding
• Motor not seated
• Motor flex folded over
• One Board not connected to SOL1 or SOL2
• Strobe board and S1/S10 not seated
• RM damaged
• Encoder wire not seated
Counter Wheel Hangs Up
Note: Counter wheel and mechanism are present, even though exposure
counter display is electronic.
Typical causes:
• Trim off plastic flash from main frame
• Bad pack pawl
• S9, S10 always making
• Motor flex retainer not seated
• LED leads too long
• Remote socket too high
• Counter spring not seated, or defective
• Pick damaged
• Defective timing gear
• Gear drive cover not seated
• Brown wire caught in counter wheel