Strobe doesn’t Fire
Typical causes:
S9 contact bent
Defective strobe
Green and orange wires reversed
Flashtube assembly defective
Orange wire not connected to strobe
White trigger wire not soldered or cold soldered
Flashtube not seated
Flashtube assembly incorrectly assembled
S1/S10 not held down in snap
Strobe Fires at Wrong Time
Typical causes:
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
LEDs don’t Light or Light at Wrong Time
Typical causes:
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
Defective LED - replace LCD module
Ranging Incorrect
Typical causes:
S9 never open
S9, S10 short on wireform switch block
Defective RM
Defective transducer
Quintic not free
Ranging in wrong units (feet/meters): check jumper W1, LCD module
Defective encoder
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
Defective LCD module

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaroid Spectra/Image One Board and is the answer not in the manual?

Polaroid Spectra/Image One Board Specifications

General IconGeneral
BrandPolaroid
ModelSpectra/Image One Board
CategoryDigital Camera
LanguageEnglish

Related product manuals