65
Blades don’t Open
Typical causes:
Shutter not seated
SOL 1 not adjusted properly
Wire connectors not connected to SOL 1 or SOL 2
Kicker spring not seated
Solenoid not seated straight
Sticky blades
No SOL 1 drive
Drive link not seated to walking beam
Encoder wire hitting SOL 2 plunger
Base block Quintic post distorted
SOL 2 plunger sticky
Wireform switch not in correct position
Broken drive link
Catch pawl hang-up
Photodiode not glued properly
SOL 2 moves in frame
Encoder lead broken
Counter wheel hang up
Door latch distorted
Black and red wires not seated to Strobe Board (J14-J15)
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
No S1 Cycle
Typical causes:
S1/S10 switch distorted
Wire connectors not seated to RM, FM, Strobe or motor flex
Defective Strobe
Poor LCD Module connection (See Poor LCD Module Connection, Page 4-9)
LCD module defective
Sticky S1/S10
Typical causes:
Button hung up on top cover insert
S1/S10 button bezel not seated

Table of Contents