Minimum distance between two base stations varies depending on
material and construction of buildings, but there must always be
synchronization chains and radio coverage overlap between the two base
stations or handover between radio units. The time it takes a person to
cross the common coverage area must be 10 seconds or more, as the
handset needs time to scan for an alternative base station.
Electrical Requirements for Base Station
The following electrical requirements must be met:
The base station operates on standard twisted pair ethernet cable - e.g.
minimum Cat.5e - to prevent disturbances from other equipment.
Maximum power supply consumption is 3.0W (IEEE 802.3af class 1
device).
The max. radiated output power for the antenna is 10mW e.i.r.p/channel.
Electrical Requirements for Repeater
The supplied power (power supply) for the charger must be 110 V to 120
V ac nominal (or 220 V to 230 V ac nominal), 50/60 Hz.