In the example below, base station No. 10 is down. As a consequence, base
station No. 11 must use the alternative sync way on No. 21.
Figure 3-4 Synchronization Chain with Alternative Sync Ways
Figure 3-5 Synchronization Chain with Alternative Sync Ways
•No. 0 is the Sync Master (can be numbered 0-255).
•No. 10 and No. 20: Primary and alternative sync on No. 0.
•No. 11: Primary sync on No. 10 and alternative sync on No. 21.
•No. 21: Primary sync on No. 20 and alternative sync on No. 11.
•No. 0 is the Sync Master (can be numbered 0-255).
•No. 10, No. 20, No. 30, and No. 40: Primary and alternative sync on No. 0.
•No. 11: Primary sync on No. 10 and alternative sync on No. 21.
•No. 21: Primary sync on No. 20 and alternative sync on No. 11.
•No. 31: Primary sync on No. 30 and alternative sync on No. 41.
•No. 41: Primary sync on No. 40 and alternative sync on No. 31.