Chapter 5 Function parameter
60
No.
Code
Parameter
name
Setting range
Factory
setting
Chan
ge
Reference
page
abnormal(
Err.16
)(same as
units digit)
274.
F8.18
Fault protection
action selection
2
Units digit: encoder/PG
card abnormal (Err.20)
0: Free stop
1
Switch to
V/F
and then
stop at the selected mode
2Switch to
V/F
and
continue to run
Tens digit: function code
read and write abnormal
(Err.21)
0: Free stop
1: Stop at the selected
mode
Hundreds digit: Reserved
Thousands digit: Motor
overheating (Err.25)
( same
as F8.17 units digit)
Ten thousands digit:
Running time
arrival(
Err.26
)( same as
F8.17 units digit)
00000
144
275.
F8.19
Fault protection
action selection
3
Units digit:User-defined
fault 1(Err.27)
( same as
F8.17 units digit)
Tens digit: User-defined
fault 2(Err.28) ( same as
F8.17 units digit)
Hundreds digit: Power-on
time arrival (Err.29)
( same
as F8.17 units digit)
Thousands digit: Load
drop (Err.30)
0: Free stop
1: Deceleration parking
2: Deceleration up to 7%
00000
144