6. Reattach the Yoke to the Ramp using the two fasteners, torque to 320 in-lbs (236.2
Nm).
7. Remove any blocking materials and/or pads.
8. Reconnect the Lift Motor input power/control cable.
9. Verify the elliptical incline operation through the full range of motion, levels 1 though 10.
10. Verify the lift motor calibration distance:
a. Access the diagnostic CROSSRAMP TEST and set the incline level to 10.
b. Disconnect the input power/control cable.
c. Measure and verify the Lift Motor calibration distance remains 9 in.
d. Reconnect the input power/control cable.
11. Do the diagnostics CROSSRAMP TEST.
12. Reinstall the Ramp cover, the Lift Interface Plate cover, and the Front Lift cover, see
"Front Lift Cover Replacement" on page49, "Lift Interface Plate Cover Replacement"
on page51, and "Ramp Cover Replacement" on page55.
13. Verify machine operation and return to service, see "Operation Verification" on page11.
Note:This procedure may have generated lift motor related error codes. Check the
error log and clear related error codes.
See Also
"Lift Motor Calibration" on page40
Experience Series 800 Line EFX
104
5 Replacement Procedures
Lift Motor Replacement