Clearing the Yellow & Yellow Pulsing ASL states
An ASL pulsing yellow state is triggered when an error code event occurs and is logged. To
clear a pulsing yellow state, the error condition causing the ASL pulsing yellow must first be
resolved either manually or the machine may resolve and self-clear the issue. A manually or
machine self-cleared error code will change the ASL state from pulsing yellow to the solid yel-
low state.
Clearing the pulsing yellow ASLstate
An ASL pulsing yellow state is triggered when an error code event occurs and is logged. To
clear a pulsing yellow state, the error condition causing the ASL pulsing yellow must first be
resolved either manually or the machine may resolve and self-clear the issue. A manually or
machine self-cleared error code will change the ASL state from pulsing yellow to the solid yel-
low state.
Clearing the solid yellow ASLstate
P10, P20, and P30 consoles:
On P10, P20, and P30 consoles, clearing the error code from the Error Log resets the ASL
state from solid yellow to the solid blue state.
P62, P80, and P82 consoles:
1. On P62, P80, and P82 consoles, the Maintenance > Operating Condition parameter
must be reset from the Inspect condition to the Normal condition. After resetting the
Operating Condition to Normal, the ASL state will change from solid yellow to the solid
blue state.
2. Then go to the CPA
1
Event Log and clear the error code by selecting the Clear control.
Note:Clearing the CPA Event Log does NOT clear the error codes from the Event
Log.
1
Control Processing Assembly
Experience Series 800 Line EFX
138
6 Troubleshooting
Active Status Light (ASL)