AFV
+
Series High Power Programmable AC Power Supply
5-100
5.5 Communication Example
5.5.1 Switch Remote/Local
Remote:02 06 00 02 00 01 E9 F9(hex)
Local:02 06 00 02 00 00 28 39(hex)
5.5.2 Switch High/Low Level
High Level:02 06 00 03 00 01 B8 39
Low Level:02 06 00 03 00 00 79 F9
5.5.3 Read Equipment Information
Read Equipment Information:02 03 00 10 00 0A C4 3B (hex)
Read Operation Mode and High/Low Status:02 03 02 00 00 02 C5 80(hex)
5.5.4 General Mode
5.5.4.1 Three-Phase Voltage Synchronized Mode
Parameters Setup:02 10 01 00 00 02 04 08 98 01 F4 72 E3(hex)
Run & Output:02 06 00 01 00 01 19 F9(hex)
5.5.4.2 Three-Phase Voltage Independent Mode
Parameters Setup:02 10 01 01 00 04 08 01 F4 08 98 08 98 08 98 DB 4B(hex)
Run & Output:02 06 00 01 00 04 D9 FA(hex)
Note
:
All the voltage value here: Real Value x 10