AFV
+
Series High Power Programmable AC Power Supply
6-111
6.5.2 INST:PHASe
Function DescriptionSetup phase angle for three-phase model
Command DescriptionINST:PHASe 0,240,120\r\n
Parameter1U phase angle (U phase reference angle defaults to 0, do not change)
Parameter2U-V phase angle
Parameter3U-W phase angle
Answer CommandNone
6.6 OUTPut Command
6.6.1 OUTPut
Function DescriptionStart/Stop output command for power source
Command DescriptionOUTPut 0|1\r\n
Parameter1Output status (1Start Output, 0Stop Output)
Answer CommandNone
6.6.2 OUTPut?
Function DescriptionQuery output status of power source
Command DescriptionOUTPut\r\n
Answer CommandOUTPut 0|1\r\n
Parameter1Output status (1Start Output, 0Stop Output)
6.7 MEASurement Command
6.7.1 MEAS:MODE
Function DescriptionSetup the measurement mode
Command DescriptionMEAS:MODE OUT\r\n
Parameter1Measurement mode (OUT- Output Side)
Answer CommandNone