AFV
+
Series High Power Programmable AC Power Supply
6-111
6.5.2 INST:PHASe
Function Description:Setup phase angle for three-phase model
Command Description:INST:PHASe 0,240,120\r\n
Parameter1:U phase angle (U phase reference angle defaults to 0, do not change)
Parameter2:U-V phase angle
Parameter3:U-W phase angle
Answer Command:None
6.6 OUTPut Command
6.6.1 OUTPut
Function Description:Start/Stop output command for power source
Command Description:OUTPut 0|1\r\n
Parameter1:Output status (1—Start Output, 0—Stop Output)
Answer Command:None
6.6.2 OUTPut?
Function Description:Query output status of power source
Command Description:OUTPut?\r\n
Answer Command:OUTPut 0|1\r\n
Parameter1:Output status (1—Start Output, 0—Stop Output)
6.7 MEASurement Command
6.7.1 MEAS:MODE
Function Description:Setup the measurement mode
Command Description:MEAS:MODE OUT\r\n
Parameter1:Measurement mode (OUT- Output Side)
Answer Command:None