6.10 Communication Example
6.10.1 Remote Control
Enter remote control modeSYST:REM\r\n
Read rated capacityLIM:POW?\r\n
Note
Read the rated capacity is used for checking if the communication works
normal and receive data successfully. (There is no answer for SYST:REMCommand)
6.10.2 Read Device Information
Read product informationSYST:INFO?\r\n
Read rated capacityLIM:POW?\r\n
Read max. voltageLIM:VOLT:HIGH?\r\n
Read min. voltageLIM:VOLT:LOW? \r\n
Read max. frequencyLIM:FREQ:HIGH? \r\n
Read min. frequencyLIM:FREQ:LOW? \r\n
Read available function listSYST:FUNC? \r\n
Read high/low level statusSOUR:VOLT:RANG:LOW? \r\n
Read running statusOUTP? \r\n
Note
User can select the needed information and send the corresponding
command in above.
6.10.3 Phase Angle Control
Setup phase angle valueINST:PHASe 0240120\r\n
Note 1: The output voltage waveform of all output mode, including the general, the
step and the gradual, are affected by the phase angle control.
Note2
The default phase angle value is
0
240
120
.