AFV
+
Series High Power Programmable AC Power Supply
6-109
6.3.12 SOUR:GRAD:PCYC
Function DescriptionSetup running cycles in Gradual Mode
Command DescriptionSOUR:GRAD:PCYC 1,12,10\r\n
Parameter1Start group No.1-12
Parameter2End group No.1-12
Parameter3Running cycles1-255
Answer CommandNone
6.3.13 SOUR:GRAD:LOAD
Function DescriptionSetup all GRAD data to controller MCU.
Command DescriptionSOUR:GRAD:LOAD\r\n
Answer CommandNone
NoteThe command is optional.
6.3.14 SOUR:SOFT:VOLT
Function DescriptionSetup Start Voltage and Rated Voltage of Soft Start function
Command DescriptionSOUR:SOFT:VOLT 5.00220.00\r\n
Parameter1Start Voltage
Parameter2Rated Voltage
Answer CommandNone
6.3.15 SOUR:SOFT:FREQ
Function DescriptionSetup Start Frequency and Rated Frequency of Soft Start
function
Command DescriptionSOUR:SOFT:FREQ 5.00,50.00\r\n
Parameter1Start Frequency
Parameter2Rated Frequency
Answer CommandNone