AFV
+
Series High Power Programmable AC Power Supply
6-109
6.3.12 SOUR:GRAD:PCYC
Function Description:Setup running cycles in Gradual Mode
Command Description:SOUR:GRAD:PCYC 1,12,10\r\n
Parameter1:Start group No.(1-12)
Parameter2:End group No.(1-12)
Parameter3:Running cycles(1-255)
Answer Command:None
6.3.13 SOUR:GRAD:LOAD
Function Description:Setup all GRAD data to controller MCU.
Command Description:SOUR:GRAD:LOAD\r\n
Answer Command:None
Note:The command is optional.
6.3.14 SOUR:SOFT:VOLT
Function Description:Setup Start Voltage and Rated Voltage of Soft Start function
Command Description:SOUR:SOFT:VOLT 5.00,220.00\r\n
Parameter1:Start Voltage
Parameter2:Rated Voltage
Answer Command:None
6.3.15 SOUR:SOFT:FREQ
Function Description:Setup Start Frequency and Rated Frequency of Soft Start
function
Command Description:SOUR:SOFT:FREQ 5.00,50.00\r\n
Parameter1:Start Frequency
Parameter2:Rated Frequency
Answer Command:None