EasyManua.ls Logo

Preen AFV+ Series - 6.7.2 MEAS:ALL?; 6.7.3 MEAS:VOLT?; 6.7.4 MEAS:CURR?; 6.7.5 MEAS:FREQ?

Default Icon
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AFV
+
Series High Power Programmable AC Power Supply
6-112
6.7.2 MEAS:ALL?
Function Description:Read output side measurement data
Command Description:MEAS:ALL?\r\n
Answer Command:
MEAS:ALL 50.0,(Output frequency)
110.0,110.0,110.0(U、V、W Three-Phase output voltage)
100.0,100.0,100.0(U、V、W Three-Phase output current)
110.0,110.0,110.0(U、V、W Three-Phase output kW)
100.0,100.0,100.0(U、V、W Three-Phase output kVAR)
110.0,110.0,110.0\r\n(U、V、W Three-Phase output PF)
6.7.3 MEAS:VOLT?
Function Description:Read output side Three-Phase voltage data
Command Description:MEAS:VOLT?\r\n
Answer Command:MEAS:VOLT 110.0,110.0,110.0\r\n
Parameter1:U Phase output voltage
Parameter2:V Phase output voltage
Parameter3:W Phase output voltage
6.7.4 MEAS:CURR?
Function Description:Read output side Three-Phase current data
Command Description:MEAS:CURR?\r\n
Answer Command:MEAS:CURR 110.0,110.0,110.0\r\n
Parameter1:U Phase output current
Parameter2:V Phase output current
Parameter3:W Phase output current
6.7.5 MEAS:FREQ?
Function Description:Read output side frequency data
Command Description:MEAS:FREQ?\r\n
Answer Command:MEAS:FREQ 50.0\r\n(Output Hz)

Table of Contents