AFV
+
Series High Power Programmable AC Power Supply
6-119
6.10.8 Read Measurement Data
6.10.8.1 Output Side
Setup measurement mode:MEAS:MODE OUT\r\n
Read system error status:SYST:ERRor? \r\n
Read measurement data:MEAS:ALL? \r\n
Read running mode parameters : MEAS:PCYC? \r\n (For Step/Gradual Mode
operation)
6.10.9 Limit Current Settings
Setup the upper limit current:LIM:CURR 100.0\r\n
Note1
:
Once the output current exceeds the set value of upper limit current, the
device stops the output and report the fault.
Note2
:
The set value of upper current limit cannot be greater than the rated current
value.
6.11 System Error Code Description
6.11.1 System Error Code
The followings are the system error information in uint 32bit corresponding to
system error status.
R-phase IGBT1 Over current fault
R-phase IGBT2 Over current fault
R-phase IGBT3 Over current fault
R-phase IGBT4 Over current fault
S-phase IGBT1 Over current fault
S-phase IGBT2 Over current fault
S-phase IGBT3 Over current fault
S-phase IGBT4 Over current fault
T-phase IGBT1 Over current fault
T-phase IGBT2 Over current fault