AFV
+
Series High Power Programmable AC Power Supply
6-107
6.3.5 SOUR:STEP:FREQ
Function Description:Setup output frequency in Step Mode
Command Description:SOUR:STEP:VOLT 1,50.0\r\n
Parameter1:Group(1-24)
Parameter2:Output frequency of the group
Answer Command:None
6.3.6 SOUR:STEP:TIME
Function Description:Setup time interval in Step Mode
Command Description:
Mode 1:
1 Hour, 1 Minute, 10.0 Second:
SOUR:STEP:TIME 1,1:1:100\r\n
Mode 2:
1 Hour, 1 Minute, 10.00 Second:
SOUR:STEP:TIME 1,1:1:1000\r\n
Answer Command:None
6.3.7 SOUR:STEP:PCYC
Function Description:Setup running cycles in Step Mode
Command Description:SOUR:STEP:PCYC 1,24,10\r\n
Parameter1:Start group No.(1-24)
Parameter2:End group No.(1-24)
Parameter3:Running cycles(1-255)
Answer Command:None
Note
:
End group No. cannot be less than Start group No.