6.2.5 SYST:FUNC?
Function Description:Read the function list from power source
Answer Command:SYST:FUNC 1,1,1,0,0,1,0,0,1\r\n
Answer Description:
Parameter1:Three-phase independent adjustment(1—Yes 0—None)
Parameter2:Step Mode function (1—Yes 0—None)
Parameter3:Gradual Mode function (1—Yes 0—None)
Parameter4:Not available
Parameter5:Phase Angle Adjustment (1—Yes 0—None)
Parameter6:High/Low Level setting (1—Yes 0—None)
Parameter7:Soft Start (1—Yes 0—None)
Parameter8:Not available
Parameter9:Current Limit Function (1—Yes 0—None)
6.3 Three-Phase SOUR Command
6.3.1 SOUR:VOLT:RANGe
6.3.1.1 SOUR:VOLT:RANGe
Function Description:Setup up High/Low level
Command Description:SOUR:VOLT:RANG 0|1\r\n
Parameter1:High/Low level(0—Low 1—High)
Answer Command:None
6.3.1.2 SOUR:VOLT:RANGe?
Function Description:Check High/Low level status
Command Description:SOUR:VOLT:RANG?\r\n
Answer Command:SOUR:VOLT:RANG 0|1\r\n
Parameter1:High/Low level(0—Low 1—High)