Do you have a question about the Preen AFV+ Series and is the answer not in the manual?
Overview of AFV+ series, technology, frequency, and applications.
Configuration, remote control, protection, input/output, and measurement features.
Detailed technical specs for AFV+ series models, incl. input/output parameters.
Visual representations of AFV+ series product external appearance.
Identifies key components and their locations on the AFV+ series chassis.
Instructions for safely unpacking the device and checking for shipping damage.
Steps for preparing the device for installation, incl. environment and connection checks.
Details on connecting computers via RS-232/RS-485/RS-422 using a 9-pin D-type connector.
Info on input voltage range, frequency, and max current requirements.
Diagrams for connecting input/output cables for three-phase and single-phase configurations.
Guidelines for selecting wire sizes for input/output connections based on model and current.
Guide for connecting the power cord to the input terminals, incl. wiring color codes.
Instructions for connecting output wires to the load, emphasizing wire gauge for current capacity.
Explanation & diagrams for enabling Remote Sensing to compensate for voltage drop over cables.
Steps for safely powering on the device after installation, incl. initial checks.
Overview of local operation via touch screen and remote operation via communication interfaces.
Guide to using the touch screen HMI for operation and data entry.
Describes MAIN page display, output settings/measurements, and how to enable output.
Procedure for setting output voltage, incl. high/low ranges and phase synchronization.
Details on setting output frequency using keypad and display.
Instructions for setting output current high limit & activating the function.
Overview of MENU page & icons for accessing SETTING, PGM, COMM, etc.
Introduces SETTING page, incl. TEST and SYSTEM subpages.
Describes TEST subpage for activating CURRENT HIGH LIMIT, SOFT START, & PHASE ANGLE CONTROL.
Steps to activate & use CURRENT HIGH LIMIT, incl. effect on MAIN page display.
Explains SOFT START feature for high starting current loads & configuration.
Describes setting phase angles between three phases for power condition simulation.
Outlines SYSTEM subpage for configuring language, touch sound, date, time, IP, and screen lock.
Steps to set operational language to English, Traditional, or Simplified Chinese.
Instructions to enable/disable touch sound feedback.
Procedure to set the current date (year, month, day).
Steps to set the current time (hour, minute, second).
How to set up/disable screen lock function using a password.
Configuration of auto screen lock timer & how to unlock screen.
Procedure for resetting the product to factory default settings.
Introduces PGM page for accessing RAMP and STEP programming modes.
Details on setting up RAMP sequences, incl. start/end voltage, frequency, and dwell time.
Instructions for setting up STEP sequences, incl. voltage, frequency, dwell time, and cycles.
Overview of COMM page for configuring RS-485, RS-232/GPIB, and Ethernet interfaces.
Configuration for RS-485, incl. COMM TYPE, PROTOCOL, and ADDR.
Configuration for RS-232/GPIB, specifying COMM TYPE, PROTOCOL, and ADDR.
Settings for RS-422, including COMM TYPE, PROTOCOL, and ADDR.
Configuration for Ethernet, incl. COMM TYPE, PROTOCOL, ADDR, and PORT.
Describes METER page, showing output measurements (voltage, current, frequency, power).
Explains EVENT page, which records error info (date, time, event).
Displays product info like manufacturer and HMI version.
Details protection functions, error codes, causes, and solutions for faults.
Intro to Preen control software for remote control of AFV+ series via interfaces.
Describes GENERAL mode interface, detailing parameter setting & output monitoring.
Explains STEP mode for setting voltage, frequency, dwell time, and cycles.
Details RAMP mode for setting voltage, frequency, dwell time, and cycles.
Explains format for writing single & multiple registers using MODBUS RTU.
Details command format for writing multiple registers in MODBUS RTU.
Specifies correct answer format for multiple register writes in MODBUS RTU.
Explains format for reading registers using MODBUS RTU, incl. success/fail answer formats.
Describes format for communication failure responses in MODBUS RTU, incl. error codes.
Provides tables mapping register addresses to parameter names for writing & reading.
Lists register addresses for reading equipment type, phase, rating, and function modes.
Provides CRC checksum calculation logic & data tables for MODBUS communication.
Provides examples of MODBUS RTU commands for common operations like mode switching & data reading.
Resets system error status using the SCPI command *RST.
Introduces SCPI commands for system control, incl. remote/local modes & error reading.
Reads available functions list using SYST:FUNC? SCPI command.
Overview of SCPI commands for controlling 3-phase source voltage & frequency.
SCPI commands for setting/checking high/low voltage range of 3-phase source.
SCPI commands for setting output voltage in 3-phase synchronized & independent modes.
SCPI command for setting output frequency in general mode.
SCPI command to set output voltage for a group in Step Mode.
SCPI command to set output frequency for a group in Step Mode.
SCPI commands for setting time intervals (delay/ramp) in Step Mode.
SCPI command for setting running cycles (start/end group, loops) for Step Mode.
SCPI command to setup all STEP data to the controller MCU.
SCPI command to setup output voltage in Gradual Mode.
SCPI command to setup output frequency in Gradual Mode.
SCPI commands for setting time intervals in Gradual Mode.
SCPI command to setup running cycles in Gradual Mode.
SCPI command to setup all GRAD data to the controller MCU.
SCPI command to setup Start Voltage & Rated Voltage for Soft Start.
SCPI command to setup Start Frequency & Rated Frequency for Soft Start.
SCPI command to setup Delay Time & Ramp Time for Soft Start.
SCPI command to select operation function mode (GEN, STEP, GRAD, THR, SOFT).
SCPI commands for instance settings, like coupling mode for 3-phase voltage.
SCPI command to setup 3-phase synchronized or independent voltage mode.
SCPI command to setup phase angles for 3-phase models.
SCPI commands to start/stop power source output & query status.
SCPI commands for setting measurement modes & reading output data.
SCPI command to read all output side measurement data at once.
SCPI command to read 3-phase output voltage data.
SCPI command to read 3-phase output current data.
SCPI command to read output side frequency data.
SCPI command to read output side 3-phase kW data.
SCPI command to read output side 3-phase kVAR data.
SCPI command to read output side 3-phase PF data.
SCPI command to read step/gradual mode running cycle numbers.
SCPI commands for reading frequency, voltage, and power limits.
Reads lower frequency limit of the power source.
Reads upper frequency limit of the power source.
Reads lower voltage limit of the power source.
Reads upper voltage limit of the power source.
Reads rated capacity (power) of the power source.
Sets the upper limit current value for the output.
Sets the upper limit power value for the output.
SCPI command to read communication status of the last command.
Provides examples of SCPI commands for remote control and reading device information.
SCPI command to enter remote control mode.
Examples of SCPI commands to read product info, capabilities, and status.
SCPI command to setup phase angle values for 3-phase output modes.
SCPI command examples for setting up General Mode parameters.
SCPI command examples for setting up Step Mode, incl. voltage, frequency, and time intervals.
SCPI command examples for setting up Gradual Mode parameters.
SCPI command examples for setting up Three-Phase Independent Output Mode.
SCPI commands for reading measurement data and system status.
SCPI command to set upper limit current & notes on behavior.
Provides list of system error codes, descriptions, and fault info.
Step-by-step procedure for calibrating output voltage accuracy using a power analyzer.
Procedure for calibrating output current accuracy using a power analyzer and resistive load.
Steps for calibrating output power accuracy using a power analyzer and resistive load.
Important notices & warnings regarding safety & precautions before performing maintenance.
| Brand | Preen |
|---|---|
| Model | AFV+ Series |
| Category | Power Supply |
| Language | English |