AFV
+
Series High Power Programmable AC Power Supply
6-104
6 SCPI Command
6.1 *RST
Function Description:Reset system error
Answer Command:None
6.2 SYST Command
6.2.1 SYST:REMote
Function Description:Switch to remote control mode
Answer Command:None
6.2.2 SYST:LOCal
Function Description:Switch to local control mode
Answer Command:None
6.2.3 SYST:ERRor?
Function Description:Read System Error Code
Answer Command:SYST:ERR 0x00000000\r\n(MEAS:MODE O\r\n 32bit)
Answer Description:32bit represent a system error. Refer to section 6.11.
Note
:
MEAS:MODE I\r\n: Answer Command 0x0000
(
16bit
)
6.2.4 SYST:INFO?
Function Description:Read the information from power source
Answer Command:SYST:INFO 1,3,3,1,1\r\n
Answer Description:
Parameter1:Model Name(1 AFV
+
)
Parameter2:Three Phase/ Single Phase Input(1—Single-Phase, 3—Three-Phase)
Parameter3:Three-Phase/ Single-Phase Output (1—Single-Phase, 3—Three-Phase)
Parameter4:Not available
Parameter5:Minimum time (0—0.01 sec, 1—1sec)