AFV
+
Series High Power Programmable AC Power Supply
6-113
6.7.6 MEAS:POWer?
Function DescriptionRead output side Three-Phase kW data
Command DescriptionMEAS:POW?\r\n
Answer CommandMEAS:POW 110.0,110.0,110.0\r\n
Parameter1U Phase output kW
Parameter2V Phase output kW
Parameter3W Phase output kW
6.7.7 MEAS:POWer:APParent?
Function DescriptionRead output side Three-Phase kVAR data
Command DescriptionMEAS:POW:APP?\r\n
Answer CommandMEAS:POW:APP 110.0,110.0,110.0\r\n
Parameter1U Phase output kVAR
Parameter2V Phase output kVAR
Parameter3W Phase output kVAR
6.7.8 MEAS:POWer:PFACtor?
Function DescriptionRead output side Three-Phase PF data
Command DescriptionMEAS:POW:PFAC?\r\n
Answer CommandMEAS:POW:PFAC 0.99,0.99,0.98\r\n3 Phase output PF
Parameter1U Phase output PF
Parameter2V Phase output PF
Parameter3W Phase output PF
6.7.9 MEAS:PCYCle?
Function DescriptionRead Step/Gradual/ Mode running cycle No.
Command DescriptionMEAS:PCYC?\r\n
Answer CommandMEAS:PCYC 1,2,00:00:08\r\n
Parameter1Running parameter No.
Parameter2Running cycle No.
Parameter3Running parameter time interval (H:M:S)