AFV
+
Series High Power Programmable AC Power Supply
6-117
6.10.4 General Mode
Setup General Mode:FUNC GEN\r\n
Setup Three-Phase Voltage Mode:INST:COUP 0\r\n
Setup High/Low Level:SOUR:VOLT:RANG 1\r\n
Setup Output Voltage:SOUR:VOLT 220.0\r\n
Setup Output Frequency:SOUR:FREQ 50.0\r\n
Start to Output:OUTP 1\r\n
6.10.5 Step Mode
Setup for Step Mode:FUNC STEP\r\n
Setup Group1 Output Voltage:SOUR:STEP:VOLT 1,220.0\r\n
Setup Group1 Output Frequency:SOUR:STEP:FREQ 1,50.0\r\n
Setup Group1 Running Time Interval:
Mode 1:
0 Hour, 0 Minute, 10.0 Second:
SOUR:STEP:TIME 1,0:0:100\r\n
Mode 2:
0 Hour, 0 Minute, 10.00 Second:
SOUR:STEP:TIME 1,0:0:1000\r\n
…..
Setup Group24 Output Voltage:SOUR:STEP:VOLT 24,220.0\r\n
Setup Group24 Output Frequency:SOUR:STEP:FREQ 24,50.0\r\n
Setup Group24 Running Time Interval:
Mode 1:
0 Hour, 0 Minute, 10.0 Second:
SOUR:STEP:TIME 24,0:0:100\r\n
Mode 2:
0 Hour, 0 Minute, 10.00 Second:
SOUR:STEP:TIME 24,0:0:1000\r\n
Setup Step Mode Start group/End group/Cycles times:SOUR:STEP:PCYC 1,24,10\r\n
Setup All Step Data:SOUR:STEP:LOAD\r\n(Optional)
Start to Output:OUTP 1\r\n