EasyManua.ls Logo

Preen AFV+ Series - 6.3.8 SOUR:STEP:LOAD; 6.3.9 SOUR:GRAD:VOLT; 6.3.10 SOUR:GRAD:FREQ; 6.3.11 SOUR:GRAD:TIME

Default Icon
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AFV
+
Series High Power Programmable AC Power Supply
6-108
6.3.8 SOUR:STEP:LOAD
Function DescriptionSetup all STEP data to controller MCU.
Command DescriptionSOUR:STEP:LOAD\r\n
Answer CommandNone
Note
The command is optional.
6.3.9 SOUR:GRAD:VOLT
Function DescriptionSetup output voltage in Gradual Mode
Command DescriptionSOUR:GRAD:VOLT 1,110.0,220.0r\n
Parameter1Group1-12
Parameter2Gradual start voltage of the group
Parameter3Gradual end voltage of the group
Answer CommandNone
6.3.10 SOUR:GRAD:FREQ
Function DescriptionSetup output frequency in Gradual Mode
Command DescriptionSOUR:GRAD:FREQ 1,50.0,60.0r\n
Parameter1Group1-12
Parameter2Gradual start frequency of the group
Parameter3Gradual end frequency of the group
Answer CommandNone
6.3.11 SOUR:GRAD:TIME
Function DescriptionSetup time interval in Gradual Mode
Command Description
Mode 1
1 Hour, 1 Minute, 10.0 Second
SOUR: GRAD:TIME 1,1:1:100\r\n
Mode 2
1 Hour, 1 Minute, 10.00 Second
SOUR: GRAD:TIME 1,1:1:1000\r\n
Answer CommandNone

Table of Contents