AFV
+
Series High Power Programmable AC Power Supply
6-110
6.3.16 SOUR:SOFT:TIME
Function Description:Setup Delay Time and Ramp Time of Soft Start function
Command Description:SOUR:SOFT:TIME 5.00,3.00\r\n
Parameter1:Delay Time
Parameter2:Ramp Time
Answer Command:None
6.4 FUNC Command
Function Description:Select operation function mode
Command Description:FUNC GEN|STEP|GARD|THR|LVRT|TRAN\r\n
Parameter1:Function abbreviation
GEN- General Mode
STEP- Step Mode
GRAD- Gradual Mode
THR- Three Phase Independent Output
SOFT- Soft Start
Answer Command:None
NOTE
:
Before send the “OUTPut” Command, please select operation function
mode.
6.5 INST Command
6.5.1 INST:COUPling
Function Description:Setup Three-Phase Synchronized / Three-Phase Independent
Voltage Mode
Command Description:INST:COUP 0|1\r\n
Parameter1:Setup voltage operation mode (0—Three-Phase Synchronized,
1—Three-Phase Independent)
Answer Command:None