-105-
COMMON
4. Bottom Group
Water Connections leak tight
Retracting mechanism
Drain gasket Floor model
Drain Connection
Quenching / Drain box
Drain valve SCC
5. Gas Specific parts
Burner
Burner blower
Emission Analysis
CO < 300ppm
CO2 according list Measured value:
Visual Inspection flue vent
6. Electrical Components
Earth Bonding
Strain relief power cord
Fuses / fuse holder
All wires tightly secured
Amp. Draw Hot Air L1: A / L2: A / L3: A
Amp Draw Steam L1: A / L2: A / L3: A
Max Temp. PCB °C
Air Filter clean
7. Dampfgenerator
Leak Tight
Level Electrode
Scale deposit in Steam
generator: Visual control
ppm
Measured value:
ppm
Connected flow pressure in
Combi mode
Hand Shower+Shower hose
(Function - non leaking)
Function o.k. Faulty Comments:
Function o.k. Faulty
Measured value:
mbar
Comments:
Function o.k. Faulty Comments:
Comments:Function o.k. Faulty
Steam generator pump /
flushing
Contacts of main contactor free
/ not welded
Page
Preventative Maintenance SCC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational SCC Line and is the answer not in the manual?

Rational SCC Line Specifications

General IconGeneral
BrandRational
ModelSCC Line
CategoryGrill
LanguageEnglish

Related product manuals