S
Fault List CM
No steam
Wet cooking mode is
activated but no steam is
visible
Door closed?
Close door and/or
check door contact
switch
Indication H2O OPEN?
Yes
Indication E16 or E17?
E16: Temperature SG>180°C
Check for scale build up
E17: Temperature SG<-5°C
Water tap open?
Sediment filter at water
connection to unit clean?
Check solenoid valve
filling Y1
Yes
ATTENTION:
Steam above 110°C is not visible, it
does not condensate on the cabinet
door!
No
Check level electrode S2 with
Diagnostic program (dP 8)
Indication = " 1 "?
Unit connected to treated water?
Indication E6 or E4?
E6: Check sensor steamgenerator B5
with diagnostic program (999°C)
E4:Check quenching sensor B2 with
diagnostic program (999°C)
Yes
No
Yes
Check steam heating
elements/SSR with Diagnostic
program .
Measure current with
clamp meter
No