EasyManuals Logo

Rational SCC Line User Manual

Rational SCC Line
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
-123-
S
Fault List CM
No steam
Wet cooking mode is
activated but no steam is
visible
Door closed?
Close door and/or
check door contact
switch
Indication H2O OPEN?
Yes
Indication E16 or E17?
E16: Temperature SG>180°C
Check for scale build up
E17: Temperature SG<-5°C
Water tap open?
Sediment filter at water
connection to unit clean?
Check solenoid valve
filling Y1
Yes
ATTENTION:
Steam above 110°C is not visible, it
does not condensate on the cabinet
door!
No
Check level electrode S2 with
Diagnostic program (dP 8)
Indication = " 1 "?
Unit connected to treated water?
Indication E6 or E4?
E6: Check sensor steamgenerator B5
with diagnostic program (999°C)
E4:Check quenching sensor B2 with
diagnostic program (999°C)
Yes
No
Yes
Check steam heating
elements/SSR with Diagnostic
program .
Measure current with
clamp meter
No
Info
Yes
No

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational SCC Line and is the answer not in the manual?

Rational SCC Line Specifications

General IconGeneral
BrandRational
ModelSCC Line
CategoryGrill
LanguageEnglish