EasyManuals Logo

Rational SCC Line User Manual

Rational SCC Line
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
-72-
S
S
C
C
Overview Service messages
Service 10 SC pump
Service 11 CDS Sensor
Service 12 CDS Sensor no signal
Service 13 Steam generator
Service 14 Level electrode - Water
Service 15 Free
Service 16 PCB with old sofware
Service 17 EEPROM faulty
Service 18 Free
Service 19 Free
Service 20 Thermocouple B1 Cabinet
Service 21 Micro switch Clima Plus
Service 22 Free
Service 23 SSR steam
Service 24 SSR hot air
Service 25 CleanJet no function - Pump
Service 26 Drain valve closed
Service 27 Drain valve doesn‘t close
Service 28 Steam generator above 180°C
Service 29 PCB temperature
Service 30 Humidity control
Service 31 Core probe
Service 32 Ignition box
Service 33 Ignition, gas supply,
Service 34 Bus signal
Intervall code of intermittent buzzer counted per 5 seconds
(broken thermocouple )
B1 12x per 5 seconds
B2 6x per 5 seconds
B4 5x per 5 seconds
B5 8x per 5 seconds
Core Probe 20x per 5 seconds

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational SCC Line and is the answer not in the manual?

Rational SCC Line Specifications

General IconGeneral
BrandRational
ModelSCC Line
CategoryGrill
LanguageEnglish

Related product manuals