Service 11
(CDS sensor)
Maintenance needed
-
Appears for 30 sec. after switch ON
-
Display can be cancelled by touch
- Water level o. k.
- Level electrode is working
-
Too many pulses from CDS sensor
- Check electrode or water leaka-
ge through check valve
Service 14
Maintenance needed
Only hot air manual possible
-
Appears for 30 sec. after switch ON
-
Display can be cancelled by touch
- Level electrode no water sensing
- CDS sensor measured enough
pulses;
- Possible reason osmosis water
treatment
Service 17
(Eeprom not initializised)
Unit without function
- Only active with pcb-SW version
01-07-09
- Data on EEPROM faulty
- New original eeprom needed
Service 21
(Micro switch ClimaPlus)
Maintenance needed
-
Appears for 30 sec. after switch ON
-
Display can be cancelled by touch
- Micro switch ClimaPlus without
function during start routine
- Manual cooking without humidity
control possible
Service 12
(CDS sensor w/o signal)
Maintenance needed
-
Appears for 30 sec. after switch ON
- Display can be cancelled by touch
- Level electrode o.k.
- Check CDS sensor for blockage
(no signal)
Service 15
Not activated
Service 18
Not activated
Service 22
Not activated
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Service messages SCC
Service 10
(SC Pump)
Maintenance needed
-
Appears for 30 sec. after switch ON
- Display can be cancelled by touch
- SC-automatic didn‘t pump off
- Check SC-pump
Service 13
Maintenance needed
- Only hot air possible
- No low water signal during last
3x5 minutes of steam production
==> fi lled by auxilliary mode
- Check 0-1 signal from level
electrode to pcb
Service 16
Update pcb software fi rst
Unit without function
-
Appears for 30 sec. after switch ON
- Only active with pcb-SW version
01-07-09 and eeprom version later
than 01-07-09 01-07-09
(Data protection Eeprom)
Service 20
(Thermocouple B1 cabinet)
Unit without function
- Appears on time
- Thermocouple broken or out of
range
- Buzzer sounds 30 seconds
- Unit without function