EasyManuals Logo

Rational SCC Line User Manual

Rational SCC Line
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
-77-
S
S
C
C
Step
60
(min: 4x20sec; max:
4x180sec)
In case of „20“ check:
70
(4x 30 sec)
In case of „60“ check:
75
(min 80sec
max 1000 sec)
In case of „12“ check:
90
(min 360sec
max 1000 sec)
100
(min: 4x20sec; max:
4x60sec
In case of „20“ check:
110
(4x 30Sec)
Step 90,100 and 110
will run 1x for each
rpm setting!
In case of „70“ check:
900
Unit status:
Controlling with all 4 fan speeds:
Steam Heating: ON 50%
• Motor: ON
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Measuring at all 4 fan speeds:
Calibration value: Steam
• Heating: ON 50%
• Motor: ON
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Step 60 and 70 will run 1x for each rpm setting!
Heating of cabinet in combi. to 193°C (380°F)
Hot air heating: ON
• Steam Heating: ON
(when Hot air off)
Motor: ON ( max rpm)
Humidity fl ap: Closed
Hot air elements, SSR, cabinet sensor
Combination 170°C (338°F)
Hot air heating: ON 50%
Steam Heating: ON (when Hot air off)
Motor: ON (max rpm)
Humidity fl ap: Closed
Controlling with all 4 fan speeds:
Steady signal of rpm and pressure
Hot air heating: ON 50%
Steam Heating: ON (when Hot air off)
Motor: ON (max rpm fi rst)
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Measuring at all 4 fan speeds:
Calibration value: Combination
Hot air heating: ON if needed
Steam Heating: ON (when Hot air off)
Motor: ON (max rpm fi rst)
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Step 90,100 and 110 will run 1x for each rpm setting!
End – Exit diagnostic program and set DIP 1 to OFF
For immediate data storage switch unit off and on
again!
Error code
20
71
60
12
71
none
20
71
70
Reason:
Value out of
allowable range;
Max time of
4x180sec exceeded
Calibration value
not in expected
range (logic)
No hot air heating
Max time of
1000sec exceeded
Value out of allo-
wable range
Max time of
4x240sec exceeded
Calibration value
not in expected
range (logic)
Status: 01.09.2005
Calibration SCC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational SCC Line and is the answer not in the manual?

Rational SCC Line Specifications

General IconGeneral
BrandRational
ModelSCC Line
CategoryGrill
LanguageEnglish

Related product manuals