Chapter6
l
None
l
Single Pole
l
Double Pole
l
CAN Switch
l
Touch Screen (Activity Monitor)
If the operator switch is in a non-functional state, the operator may opt to use the touch
screen activity monitor. The activity monitor uses input on the touch screen to reset a seven
minute timer. If the timer does expire, the system will disable automated steering until the
operator touches the screen and reengages the steering system.
Lower Limit
Use this setting to set the lower voltage limit. This is the voltage at which the switch will
toggle when the operator is seated or the Activity Monitor is enabled.
Upper Limit
Note: The upper limit field is only used with the double pole switch type.
Use this setting to adjust the upper voltage limit. Set the upper limit so that the current
voltage reading remains below the upper limit while the operator is seated. If the presence
switch voltage exceeds the upper limit, the presence switch will disengage steering.
GPS (GNSS) Setup Tab
Note: Some pages and options may differ based upon how the machine or implement is
configured.
To access the GNSS correction settings and options available for Raven auto-steer
applications.