Manual No. 016-0171-122 Rev. I 231
Mapping the Booms
1. From the Viper Pro main screen, touch Menu, and Setup, Boom.
2. Touch Next until the Boom Setup Summary screen is displayed.
3. Select the Map Booms button. The Map Booms to Wiring Setup screen will display.
The ‘Viper Boom’ column displays the number of the boom sense sections configured for the current
configuration. These numbers correspond to the section values displayed from left-to-right on the Viper Pro
main screen.
Note: Touch the Next button if necessary to display ‘Wired As’ and ‘Display Character’ settings for
sections 6 through 10.
4. Use the ‘Wired As’ column to set the actual boom sense wired connection for each configured section.
Note: Raven boom sense wires are color coded as follows:
Viper will not allow ‘Wired As’ sections to be skipped. For example, if the value entered as the
Number of Boom Sections setting is set to 3, ‘Wired As’ must be 1, 2, and 3 in any order. These
three sections cannot be ‘Wired As’ 1, 2, and 4. To skip a boom section, a boom must be
configured with ‘0’ width.
17. Use the ‘Display Character’ column to customize the “Booms” display on the Viper Pro main screen. For
example, the display character for section 1 may be set to L to signify that section 1 is the left fence row.
Note: Use only the characters 0, 1, 2, 3, 4, 5,6, 7, 8, 9, D, E, L, R, and * to label the booms. It is
recommended to use * for skipped booms.
18. The following table is an example of a possible boom mapping configuration.
Section
Number
Lead Wire
Color
Section
Number
Lead Wire
Color
1. Black 9. White/Blue
2. Brown 10. Pink
3. Blue 11. Yellow/White
4. Black/White 12. Green/White
5. Brown/White 13. Red/White
6. Blue/White 14. White/Yellow
7. White/Black 15. White/Green
8. White/Brown 16. White/Red