Testing the Speed Sensor Cable
1. Touch Product Control.
2. Touch the Miscellaneous box. Enter 1000 as the Speed Cal and touch OK.
3. Touch OK to return to the CAN Controller Status screen.
4. Touch Tally Registers.
5. Touch the Reset button next to the Distance box.
6. With a small jumper wire (or paper clip), short between the 10 o’clock and 6 o’clock sockets with a ‘short-no-
short’ motion. Each time contact is made, the Distance total should increase by increments of 1 or more.
7. If the Distance total does not increase, remove the section of cable and repeat the test at the connector that
is the next closest to the node. If the distance total now increments during the short-no-short test, replace
the defective cable as required.
8. If no pulses are registered, perform the above voltage checks.
9. If all of the cables test ‘good’, replace the Speed Sensor.
Note: After testing is complete, re-enter the correct Speed Cal and Speed Sensor type before starting
application.