16 Technical Data RT100 Control System
Inputs
RT100 Control System
Temperature sensor
Outlet:
Pt 100
External (consumer):
Optionally Pt100 (2- or 3-conductor), J (Fe-CuNi), K (NiCr-Ni), T (Cu-
CuNi) or N (NiCrSi-NiSi) (Option), 20mA
Inlet:
Pt 100 (2- or 3-conductor)
External set-point value specifica-
tion
Standardised and scalable, analog interface with 0/4-20 mA or 0-10 VDC
External heating-cooling command
Device On/Off
Program On/Off
Signal via potential-free contacts (option)
Set-point value toggling
Signal via keyboard (F3 key, standard) or via potential-free external con-
tact (option)
Analog input
Electrically isolated analog set-point value input with scalable signal 0/4-
20 mA or 0-10 VDC (option)
Outputs
RT100 Control System
Heating/cooling Triac outputs for circuit breakers or valves or solid-state relays (SSR)
Relay functions
1 relay (standard), programmable as common alarm or as individual func-
tions (e.g. temperature switching point, deviation etc.)
3 relays (digital option), programmable as common alarm or as individual
functions (e.g. temperature switching point, deviation etc.)
Analog outputs
Electrically isolated analog outputs with scalable signal 0/4-20 mA or 0-10
VDC. An actual or set-point value can be assigned to every output. A
thermal e.m.f. of a J-, K-, T- or N-element corresponding to the current
display-actual can be output as the actual value output (option)
Data Interfaces (Option)
RT100 Control System
Data transmission to control com-
puter (hardware)
Various serial interfaces, Profibus DP, Euromap 66, Profinet-IO
Display
RT100 Control System
Construction, design
Black LCD display with white lettering. Simultaneous display of actual and
set-point values, three additional lines for important display values as well
as one status line
Fault Indications Are shown in the display unit