V 01/2016
22 Parameterisation RT100 Control System
Ramp program - Overview
Set-point
Parameter Range Remarks
Set-point at startup
Last set-point value
Upon switching on the temperature control unit, control
takes place on the selected set-point value
Always SP1
Always SP2
Set-point 1
Upon switching on, control is on the basis of the chosen
set-point value temperature 1 (SP1)
Set-point 2
Upon switching on, control is on the basis of the chosen
set-point value temperature 2 (SP2)
Set-point ramps (Soft-
ware option)
Set-point ramp heat-
ing
Selection of the set-point ramp heating (Gradient, Filter
or Inactive)
Gradient heating Setting in °C/min
Filter time constant heat-
ing
Setting in sec.
Set-point ramp cool-
ing
Selection of the set-point ramp heating (Gradient, Filter
or Inactive)
Gradient cooling Setting in °C/min
Filter time constant cool-
ing
Setting in sec.
Set-point ramps
Evacuation time
Parameter Remarks
Evacuation time Evacuation time duration (0-500 sec.)