66 RT100 Control System - Maintenance/repair RT100 Control System
RT100 Control System
Parameter Menu Structure
Show actual values
Select language
User settings
Monitoring
Interfaces
Temperature control
Pressure control
Pump regulation
Unit configuration
Inputs
Outputs
Relay
Collective alarm
Save/Load
Code
Options
Current monitoring heating
Service menu
Multiflow
Show actual values
Outlet temperature
External temperature
Inlet temperature
Heat./cool. power
Flow rate
Pump pressure
Pressure set-point
System pressure
Outlet pressure
Pump current L1
Pump current L2
Pump current L3
Operating hours
Next service
Interface
Address
Date
Time
Num. level 1 low
Control cabinet temp.
Software version
Corr. set-point
Flow deviation
Select language
German
English
French
Italian
Spanish
Dutch
Czech
Chinese
Russian
Slovenian
Polish
Danish
Hungarian
Croatian
Romanian
Portuguese
Swedish
Japanese
User settings
Display
Clock
Switch clock
Ramp program
Set-point
Evacuation time
Next service
Pump regulation
USB Logging
Monitoring
Temperature deviation
Max. heat./cool. time
Minimum flow rate
Flow deviation
Min. system pressure
Interfaces
Address
Change protocol
Pressure control
Pressure control
Max. system pressure
Set-point
Pressure balance
Pressure increase
Pressure decrease
Pump regulation
Control type
Operating mode
Pump pressure set-point
Max. set-point
Min. set-point
Neutral zone
Kp
Reset time
Derivative time
Max. output
Min. output
Hand-value
Unit configuration
Device type
Max. device temp.
Max. set-point
Behaviour after power failure
Closing temperature
Pressure release
Switch off
Emptying
Leak stop
Pump
Boost pump
Heating
Cooling
Level
Flushing
Inputs
Temperature sensor Sn1
Temperature sensor Sn2
Temperature sensor Sn3
Pressure sensor 1, system
Pressure sensor 2, outlet
Flow rate
Flow monitor
Temp. monitor cooling
Analog input
Ext. Start/Stop command
Diff. pressure filter
Outputs
24 VDC outputs
Analog output 1
Analog output 2
Rela
y
Relay K1
Relay K2
Relay K3
Relay K4
Collective alarm
Alarm repeating time
Heating 1
Heating 2
Min. flow rate
Flow deviation
Flow monitor
Level
Pump current
Temp. monitor cooling
Current monit. Heating
SSR DC aux. cont.
Save
/
Load
Load user setting 1
Save user setting 1
Load AIC factory settings
Save AIC factory settings
Load factory settings
Save factory settings
Load settings from USB stick
Save settings to USB stick
Load characterist. curve F1000
Code
User password
Technician password
Service password
Reset passwords
Options
Hardware options
Software options
Activate options
Serial number
Current monit. heating
Current monitoring
Settings
Heating current L1
Heating current L2
Heating current L3
Service menu
Software versions
Delete alarm list
IO Test
Temperature control
Control type
Outlet control parameter
Control parameter cascade
Settings