PG-FP5 CHAPTER 8 USAGE COMMUNICATION COMMANDS
R20UT0008EJ0400 Rev. 4.00 Page 174 of 240
Jul 15, 2010
8.5.8 gos command
Obtains the information of flash option get for the target device.
Input format
'gos'
Description of the function
Obtains the information set by executing the [Get Flash options] command on the [Device] menu of the programming
GUI.
Example of usage
Command Status Status LED Message display Screen output
Display after executing the command
[When completed normally]
PASS
Returns to the display
before executing the
command.
[Display example]
Security Flag: xx
Boot Block Number: xx
FS area: xxxx - xxxx
OCD-ID : xxxxxxxxxxxxxxxxxxxxxxxx
Option Bytes : xxxxxxxx
PASS
Get Option Setting operation finished.
gos
Display after executing the command
[When terminated abnormally]
ERROR
ERROR: xxx
xxxxxxxxxxxxxxxx
ERROR(Exxx): <text>