ERROR CODES
SM 13 B779
Fax Option
B779
Code Meaning Suggested Cause/Action
0-76
The calling terminal fell back
to T.30 mode, because it
could not detect a JM in
response to a CM
(CM timeout).
The called terminal could not detect a CM due to
noise, etc.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
0-77
The called terminal fell back
to T.30 mode, because it
could not detect a CJ in
response to JM
(JM timeout).
The calling terminal could not detect a JM due to
noise, etc.
A network that has narrow bandwidth cannot pass
JM to the other end.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
0-79
The called terminal detected
CI while waiting for a V.21
signal.
Check for line noise or other line problems.
If this error occurs, the called terminal falls back to
T.30 mode.
0-80
The line was disconnected
due to a timeout in V.34
phase 2 – line probing.
0-81
The line was disconnected
due to a timeout in V.34
phase 3 – equalizer training.
0-82
The line was disconnected
due to a timeout in the V.34
phase 4 – control channel
start-up.
0-83
The line was disconnected
due to a timeout in the V.34
control channel restart
sequence.
The guard timer expired while starting these
phases. Serious noise, narrow bandwidth, or low
signal level can cause these errors.
If these errors happen at the transmitting terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using
dedicated tx parameters.
Try increasing the tx level.
Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the rx cable equalizer setting.
Try increasing the tx level.
Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
0-84
The line was disconnected
due to abnormal signaling in
V.34 phase 4 – control
channel start-up.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-85
The line was disconnected
due to abnormal signaling in
V.34 control channel restart.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-86
The line was disconnected
because the other terminal
requested a data rate using
MPh that was not available
in the currently selected
symbol rate.
The other terminal was incompatible.
Ask the other party to contact the manufacturer.
0-87
The control channel started
after an unsuccessful
primary channel.
The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
This does not result in an error communication.
0-88
The line was disconnected
because PPR was
transmitted/received 9
(default) times within the
same ECM frame.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.