B779 14 SM
Code Meaning Suggested Cause/Action
2-11
Only one V.21 connection
flag was received
Replace the FCU.
2-12 Modem clock irregularity
Replace the FCU.
2-13 Modem initialization error
Turn off the machine, then turn it back on.
Update the modem ROM.
Replace the FCU.
2-23
JBIG compression or
reconstruction error
Turn off the machine, then turn it back on.
Replace the EXFUNC board if the error is
frequent.
2-24 JBIG ASIC error
Turn off the machine, then turn it back on.
Replace the EXFUNC board if the error is
frequent.
2-25
JBIG data reconstruction
error (BIH error)
2-26
JBIG data reconstruction
error (Float marker error)
2-27
JBIG data reconstruction
error (End marker error)
2-28
JBIG data reconstruction
error (Timeout)
JBIG data error
Check the sender’s JBIG function.
Update the MBU ROM.
2-29
JBIG trailing edge maker
error
FCU defective
Check the destination device.
2-50
The machine resets itself for
a fatal FCU system error
If this is frequent, update the ROM, or replace the
FCU.
2-51
The machine resets itself
because of a fatal
communication error
If this is frequent, update the ROM, or replace the
FCU.
2-53
Snd msg() in the manual
task is an error because the
mailbox for the operation
task is full.
The user did the same operation many times, and
this gave too much load to the machine.
4-01 Line current was cut
Check the line connector.
Check the connection between FCU and NCU.
Check for line problems.
Replace the FCU or the NCU.
4-10
Communication failed
because of an ID Code
mismatch (Closed Network)
or Tel. No./CSI mismatch
(Protection against Wrong
Connections)
Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
The machine at the other end may be defective.
5-10 DCR timer expired
Replace the FCU.
5-20
Storage impossible because
of a lack of memory
5-21 Memory overflow
Temporary memory shortage.
Test the SAF memory.
Replace the FCU or optional EXMEM board
5-23
Print data error when
printing a substitute rx or
confidential rx message
Test the SAF memory.
Ask the other end to resend the message.
Replace the FCU or optional EXMEM board.
5-25 SAF file access error
Replace the FCU or EXMEM board.