BIT SWITCHES
B779 64 SM
Communication Switch 10 SP No. 1-104-017
No FUNCTION COMMENTS
0
to
7
Memory transmission:
Maximum number of dialing
attempts to the same
destination
01 – FE (Hex) times
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 SP No. 1-104-019
No FUNCTION COMMENTS
0
to
7
Memory transmission: Interval
between dialing attempts to the
same destination
01 – FF (Hex) minutes
Communication Switch 13 – Not used (do not change the settings.)
Communication Switch 14 SP No. 1-104-021
No FUNCTION COMMENTS
0
Inch-to-mm conversion during
transmission
0: Disabled 1: Enabled
0: In immediate transmission, data scanned in inch
format are transmitted without conversion.
In memory transmission, data stored in the SAF
memory in mm format are transmitted without
conversion.
Note: When storing the scanned data into SAF
memory, the fax unit always converts the data into
mm format.
1: The machine converts the scanned data or stored
data in the SAF memory to the format which was
specified in the set-up protocol (DIS/NSF) before
transmission.
1-5 Not used Do not change the factory settings.
6
to
7
Available unit of resolution in
which fax messages are
received
Bit 7 Bit 6 Unit
0 0 mm
0 1 inch
1 0 mm and inch
(default)
1 1 Not used
For the best performance, do not change the factory
settings.
The setting determined by these bits is informed to
the transmitting terminal in the pre-message
protocol exchange (in the DIS/NSF frames).
Communication Switch 15 – Not used (do not change the settings)