BIT SWITCHES
SM 65 B779
Fax Option
B779
Communication Switch 16 SP No. 1-104-023
No FUNCTION COMMENTS
0 Not used Do not change the settings.
1
Optional G3 unit (G3-2)
0: Not installed
1: Installed
Change this bit to 1 when installing the first optional
G3 unit.
2 Not used
3 Select PSTN connection
0: Off
1: On
This switch enables the G3-2.
0: Off, no connection
1: Recognizes and enables G3-2.
This switch can be used only after G3-2 has been
installed.
4-7 Not used Do not change the settings.
Communication Switch 17 SP No. 1-104-024
No FUNCTION COMMENTS
0 SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker’s machine
using the SEP (Selective Polling) signal is disabled.
1 SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker’s
machine using the SUB (Sub-address) signal is
disabled.
2 PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD (Password)
signal reception.
3-6 Not used Do not change the settings.
7
Action when there is no box
with an F-code that matches
the received SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Change this setting when the customer requires.
Communication Switch 18 - Not used (do not change the settings)