Adjusting Registration
1. Place the test chart on the exposure glass. Make sure that the test chart is aligned with the rear and
left scales on the exposure glass.
2.
Make a copy.
3. Measure the distance between the leading edge of the image area and the leading edge of the
paper [A].
The diagram shows the paper on the copy tray. Note that the paper is output with the face
down.
4.
Adjust the leading-edge scan registration. (SP4-010-001).
SP Specification
SP4-010-001 (LE Scan Regist) 0 ± 2 mm
5. Measure the distance between the side edge of the image area and the side edge of the paper [B].
6.
Adjust the side-to-side registration (SP4-011-001).
SP Specification
SP4-011-001 (S-to-S Scan Regist) 0 ± 2 mm
Adjusting Copy Image Area
137