SP-9XXX (Etc)
9001 Right Door Detect [0 to 1 / 0 ]
001 0: NOT SET 1: SET Selects the right door open/close SW ON/OFF
9901 Fusing Temperature Setting
010 Heater Force OFF Timing
[0 to 99 / 17 / 1 mm/step ]
Sets the forced the heater OFF time after paper-
through.
011
Thresh: Warming-up Low
Temperature
[0 to 50 / 16 / 1 deg/step ]
Sets the basic temperature for determination of the
condition on machine-startup.
012 Disable Change Time
[0 to 999 / 5 / 1 sec/step ]
Unused. DO NOT change the setting.
013 Total Count Clear Time
[0 to 999 / 15 / 1 sec/step ]
When the wait time is over this SP’s time, the following
three items are reset:
Control cycle on printing,
Repeat-temperature correction,
CPM-down counter
014 Print Prepare Time
[0 to 999 / 60 / 1 sec/step ]
Sets the print preparation time.
9902
Target Temp revise (Temp)
Sets the fusing additional temperature for the temperature correction. (Pattern A)
001 Added Temp: T1 [0 to 50 / 5 / 1 deg/step ]
002 Added Temp: T2 [0 to 50 / 15 / 1 deg/step ]
003 Added Temp: T3 [0 to 50 / 10 / 1 deg/step ]
004 Added Temp: T4 [0 to 50 / 5 / 1 deg/step ]
System Service Mode