No.
Definition
Symptom Possible Cause
995 B
Model information error
NOT according manufacturing number
(11 digits) with product identification
code.
• Defective BICU
•
Defective NVRAM
• Defective controller
SC Code Descriptions
SC6xx
No.
Definition
Symptom Possible Cause/Countermeasure
632 C
MF accounting device error 1
The machine sends a data frame. No
normal end signal returns. This
symptom happens three times.
• Defective or broken line between
machine and device
633 C
MF accounting device error 2
The machine is communicating with the
accounting device. The break signal
returns.
• Defective or broken line between
machine and device
634 C
MF accounting device error 3
A backup RAM error is reported from
the accounting device.
• Defective accounting device
controller
•
Defective battery in the accounting
device
635 C
MF accounting device error 4
A battery voltage error is reported from
the accounting device.
• Defective accounting device
controller
•
Defective battery in the accounting
device
SC Tables
169