Scanner Unit
To clean the mirrors and lenses, use a blower brush or wet cotton.
Scanner Cover and Exposure Glass
Exposure glass is united with Scanner cover.
To clean the exposure glass, use alcohol or glass cleaner.
1. Platen cover or ARDF ( p.122 "ARDF Unit")
2.
Scanner front cover [A] (Hook)
The front scanner cover is attached by 2 of the hooks the picture [1] shows. Pulling the cover
downward to keep the hooks off while removing, makes detaching easy.
3. Scanner cover [B] ( x 7, Hook)
LED Unit
Do not disassemble the LED Unit. The LED Unit is precision adjusted before shipment.
Do not touch the screws on the CCD. The CCD is precision adjusted before shipment.
Do not wipe the oil coated on the guide rod off. The oil doesn't exist in service parts.
Scanner Unit
83